Products
Size: ① Motherboard, ③LCD module: PCB→Φ78mm; ② Sensor integrated probe: PCB→Φ36mm; Sensor standard 4 series or 7 series
Model Click to consult| 
					 Weight  | 
				
					 0.6kg  | 
			
| 
					 Sensor type Standard  | 
				
					 4 series, 7 series electrochemical sensor, infrared sensor, catalytic combustion sensor, PID sensor  | 
			
| 
					 Power supply  | 
				
					 two-point calibration  | 
			
| 
					 oxygen(O2)  | 
				
					 12-24VDC  | 
			
| 
					 Output  | 
				
					 4-20mA, RS485, relay  | 
			
| 
					 Sampling mode  | 
				
					 diffusion  | 
			
| 
					 Display  | 
				
					 2.0 inch HD LCD color screen  | 
			
| 
					 User Guide  | 
				
					 LCD panel buttons, infrared remote control  | 
			
| 
					 Operating temperature  | 
				
					 -20°C ~ 55°C  | 
			
| 
					 Humidity  | 
				
					 0-95% Relative humidity (non-condensing)  | 
			
| 
					 Number of relays  | 
				
					 Up to 3 relays, Max. 30V,2A  | 
			
1. Terminal definition
| 
					 Terminal number  | 
				
					 Definition  | 
				
					 Terminal number  | 
				
					 Definition  | 
			
| 
					 J1-24V  | 
				
					 Input power +  | 
				
					 J3-C3  | 
				
					 The fault relay is normally closed  | 
			
| 
					 J1-GND  | 
				
					 Input power -  | 
				
					 J3-M3  | 
				
					 Fault relay common end  | 
			
| 
					 J1-4-20mA  | 
				
					 Output current +  | 
				
					 J3-O3  | 
				
					 The fault relay is normally on  | 
			
| 
					 J1-RS485A  | 
				
					 Output RS485A  | 
				
					 J4(++)  | 
				
					 Sound and light alarm +  | 
			
| 
					 J1-RS485B  | 
				
					 Output RS485B  | 
				
					 J4(--)  | 
				
					 Sound and light alarm -  | 
			
| 
					 J1-M1  | 
				
					 Low alarm relay common end  | 
				
					 
  | 
				
					 
  | 
			
| 
					 J1-O1  | 
				
					 The low alarm relay is normally on  | 
				
					 
  | 
				
					 
  | 
			
| 
					 J1-M2  | 
				
					 High alarm relay common end  | 
				
					 
  | 
				
					 
  | 
			
| 
					 J1-O2  | 
				
					 The high alarm relay is normally on  | 
				
					 
  | 
				
					 
  | 
			
	
Note: J4 can only be connected to the horn and light alarm below 24V-100mA, and the high-power horn and light alarm can be connected
Can start or damage the drive circuit.
	
  TEL:18995278133ADD:Block A, Yinchuan Zhongguancun Innovation Center, Xingzhou Street, Xixia District, Yinchuan, Ningxia